ControlX Medical X-Ray Generators
 |
|
|
| Larger Image |
|
Brochure |
|
| |
|
|
The Milestone high frequency generator is developed to match the rigorous use of busy radiology departments, private practices with today's newest technology. The soft touch membrane key panel provides a clean, easy to use generator control design with flexibility in powering a variety radiographic applications. Integrated self diagnostic ensures ensures easy trouble free operation and easy service.
|
Specifications
|
| Power Rating |
30-80 kW |
| kV range |
40-150 kVp |
| mA range |
20-1000 mA (depending on the generator power) |
| mAs range |
0.4-600 mAs |
| Exposure time |
3 ms-6 sec. |
| Fluoroscopic kV |
40-120 kV |
| Fluoroscopic mA |
0.5-10 mA (25 mA in Pulse Fluoroscopy) |
| Power Requirements |
From 240 VAC single to 480 three phase |
Features
|
|
- Microprocessor control delivers reliability and accurate exposure parameter management.
- APR operating mode with 100 examination distributed across 10 anatomical regions. Simple and user-friendly technique reprogramming on site.
- Manual three factor factor selection permits the operator to modify the recommended kV, mA and time.
- Easy Auto-Calibration reduces initial installation time.
- Automatic tube protection.
- Sophisticated self-diagnostic capability and coded error messaged allow for fast and well-defined initial diagnostics.
- Compact console is ideally suited for small control rooms.
- Automatic tube overload protection, selectable 80% or 100%.
- Automatic Exposure Control can support either four solid state detectors or ion chambers.
- Automatic Brightness Stabilizer produces optimal fluoroscopic images.
- Supports one or two x-ray tubes in either radiographic or radiographic and fluoroscopic mode.
 |
|
|
| Larger Image |
|
Brochure |
|
| |
|
|
The PCX HF high frequency generator family matches the needs of busy radiology departments with today's technology. The coherence of touch screen and color LCD display offers a unique generator control with great flexibility in powering a variety radiographic and fluoroscopic applications. The integrated self diagnostic ensures trouble free operation and comprehensive service.
|
Specifications
|
| Power Rating |
30-80 kW |
| kV range |
40-150 kVp |
| mA range |
20-1000 mA (depending on the generator power) |
| mAs range |
0.4-600 mAs |
| Exposure time |
3 ms-6 sec. |
| Fluoroscopic kV |
40-120 kV |
| Fluoroscopic mA |
0.5-10 mA (25 mA in Pulse Fluoroscopy) |
| Power Requirements |
From 240 VAC single to 480 three phase |
Features
|
|
- Microcontroller and computer integration deliver reliability and accurate exposure parameter management.
- APR operating mode with 160 examination distributed across 8 anatomical regions. Simple and user-friendly technique reprogramming on site.
- Automatic parameter correction for patient thickness, tissue density, film.screen speed and source image distance.
- Manual override technology permits the operator to modify the recommended kV, mA and time.
- Sophisticated self-diagnostic capability and descriptive error messaged allow for fast and well-defined initial diagnostics.
- Compact display console is ideally suited for small control rooms.
- Comprehensive service program provides accurate troubleshooting and minimize downtime.
- Automatic tube overload protection, selectable 80% or 100%.
- Automatic Exposure Control can support either four solid state detectors or ion chambers.
- Automatic Brightness Stabilizer produces optimal fluoroscopic images.
- Supports one or two x-ray tubes in either radiographic or radiographic and fluoroscopic mode.
 |
|
|
| Larger Image |
|
Brochure |
|
| |
|
|
The ConRad high frequency generator is developed to match the rigorous use of small but busy radiology departments with today's newest technology. The membrane switch surface offers a clean, easy to use generator control design with flexibility in powering a variety radiographic applications. Integrated self diagnostic ensures ensures easy trouble free operation and easy service.
|
Specifications
|
| Power Rating |
20-30 kW |
| kV range |
40-125 kVp |
| mA range |
25-300 mA (20 kW), 25-400 mA (30 kW) |
| mAs range |
0.05-600 mAs |
| Exposure time |
3 ms-6 sec. |
| Power Requirements |
208/240 VAC single phase |
Features
|
|
- Microprocessor control delivers reliability and accurate exposure parameter management.
- Manual three factor factor selection permits the operator to modify the recommended kV, mA and time.
- Easy Auto-Calibration reduces initial installation time.
- Automatic tube protection.
- Sophisticated self-diagnostic capability and coded error messaged allow for fast and well-defined initial diagnostics.
- Compact console is ideally suited for small control rooms.
- Automatic Exposure Control can support two ion chambers.
- Compact design fits into small x-ray rooms.
|
|
|
|
|